Trends and Technology

Trends and Technology

HEMOLUNG RAS- Fully Integrated Respiratory Dialysis System

This system Combines advanced technology with user-centered design to provide simple, effective, and minimally invasive extracorporeal CO2removal (ECCO2R) for therapy in respiratory failure. Removing carbon dioxide and delivering oxygen directly to the blood avoids intubation and facilitates protective ventilation. It has three integrated parts:

Hemolung Cartridge – Integrated centrifugal pump creates blood flows and active mixing technology enhances CO2 removal at low blood flow rates. Advanced dual-layer membrane coating (siloxane/ heparin) ensures steady gas exchange.

 Hemolung Catheter • 15.5 Fr diameter with low resistance and kink resistant. Available in femoral (26 cm) and jugular (17 cm) versions

Hemolung Controller Intuitive user interface with on-screen instructions.  Has real-time display of CO2 removal and blood flow with automatic gas switching (O2 /air) and membrane condensation removal for steady gas exchange.

ALung- Technologies,- Pittsburg,- PA,- USASource: ALung Technologies, Pittsburg, PA, USA

Website: www.alung.com

 

Dechoker sucks the food stuck in the Airways

Dechoker is a device that applies negative pressure to the mouth creating a vaccuum, thus, sucking out whatever is blocking the airway. The vacuum pulls the lodged object towards the device. The device can be used by struggling persons on themselves too. The adult as well as toddler version is available.

Dechoker -LLC,- 13011- W -Hwy- 42- Suite- 103,- Prospect,- KY -40059

Source: Dechoker LLC, 13011 W Hwy 42 Suite 103, Prospect, KY 40059

e- mail- www.dechoker.com

Optical Probe to monitor blood oxygen saturation

Central venous oxygen saturation (SCvO2) is frequently monitored for evidence of hypovolemic and septicemia shock by taking blood sample from internal jugular vein. This non- invasive optical probe measures continuous tissue blood oxygen saturation (StO2) over the jugular vein area with the help of   infrared detectors and LED illumination that produces light at three different wavelengths. It is placed over the jugular vein with the help of ultrasound.

Source: University of Science and Technology of China.

E-mail: www.osa.org

University -of -Science and -Technology of China.University -of -Science -and -Technology -of -China.

Mask that Keeps Waste Anesthesia Gas Away from Clinicians in PACU

Mask- that- Keeps- Waste- Anesthesia- Gas- Away- from -Clinicians- in -PACU

  • Teleflex Medical(Research Triangle Park, NC) received FDA clearance for its ISO-Grad anesthesia mask that recovers much of the exhaled gas and sends it to the vacuum exhaust. The system works by running oxygen through the breathing area in one direction while exhausting using a negative pressure tube at the bottom of the mask, effectively separating the inhaled gas from the exhaled. Provide unidirectional flow of oxygen through mask to ensure maximum FIO2 and has a separate port for CO2

 

E mail- www.teleflex.com

Source: Teleflex 3015 Carrington Mill Boulevard Morrisville, NC

Air Purge System for Removing Air Bubbles from IV Lines

Anesthesia Safety Products, a Woburn, MA firm, introduced Air Purge System which is the device for automatic removal of air bubbles from IV lines. It is able to detect air bubbles moving through the line and sends them to a reservoir that is emptied into a collection bag. It is capable of removing bubbles as small as 25 micro-liters at infusion rates up to 600 ml/min.

Source: Anesthesia Safety Products, LLC
300 Trade Center, Suite 5400,
Woburn, MA 01801

Website: http://www.aspamerica.com/

RescQUECPR- device

RescQUECPR device

A system comprising of impedance threshold device and active compression decompression device to be used in CPR has received FDA approval. It provides optimal chest compressions and pulls off chest after each compression thus, maximizing effectiveness.

Zoll- Medical -Corporation,- USA

Source: Zoll Medical Corporation, USA

Website: www.zoll.com, degan@zoll.com